Midi Bolt Down Fuse (100V) (PBFT-100V-In)

General Specifications

TOP & BOTTOM HOUSING (100A-200A) PPA, 30% GLASS FILLED UL94-V0
STRIP : COPPER, Sn PLATED/ PRE- Sn PLATED
RIVET ALUMINUM/CARBON STEEL
VOLTAGE RATING : 100V DC
INTERRUPTING RATING : 2500A @ 100V DC
REFERENCE STANDARD : ISO 20934
OPERATING TEMPERATURE : -40℃ – 120℃
MOUNTING TORQUE M8 : 10Nm ± 1Nm (TO BE TIGHTENED/MOUNTED WITH DIGITAL TORQUE-WRENCH)
PULL STRENGTH 70N MIN
PACKING DETAILS : TRAY PACKING (40No’s/TRAY)

Time-Current Characteristic

TIME-CURRENT CHARACTERISTIC (30A-200A)
% OF AMPERE RATING (A) OPERATING TIME
MIN MAX
100% 100 hrs. –
135% 300 sec. 3600 sec.
150% 90 sec. 500 sec.
200% 1 sec. 50 sec.
300% 0.3 sec. 4 sec.
500% 0.1 sec. 1 sec.
600% 0.07 sec. 0.7 sec.

NOTE:
THE FUSE CHARACTERISTICS MAY CHANGE DEPENDING ON THE CONDITIONS OF USE. (Ambient Temperature, cable size/connection, fuse holder/mounting, electrical connections and prospective fault current).

TIME-CURRENT CHARACTERISTIC CURVE


Time-Current Characteristic Curve

Typical Derating Of Fuse Melting(30A - 200A)


Typical Derating Of Fuse Melting

Product Details & Part Numbers

Ampere Rating(A) Part Number Cold Resistance Cable size as per ISO 20934
30A PBFT-100V-30A 1.55 mΩ 2.5 mm²
40A PBFT-100V-40A 1.35 mΩ 4 mm²
50A PBFT-100V-50A 1.0 mΩ 6 mm²
60A PBFT-100V-60A 0.73 mΩ 6 mm²
70A PBFT-100V-70A 0.65 mΩ 10 mm²
80A PBFT-100V-80A 0.57 mΩ 10 mm²
100A PBFT-100V-100A 0.45 mΩ 10 mm²
125A PBFT-100V-125A 0.335 mΩ 16 mm²
150A PBFT-100V-150A 0.275 mΩ 25 mm²
175A PBFT-100V-175A 0.28 mΩ 25 mm²
200A PBFT-100V-200A 0.22 mΩ 35 mm²

Company Presentation